地县一体化继电保护定值在线校核系统的研究及应用Study and Application of Online Check System of Integrated Prefecture-County Relay Protection Setting Value
王祎,胡铁军,范黎敏,李雪冬,郑朋
WANG Yi,HU Tiejun,FAN Limin,LI Xuedong,ZHENG Peng
摘要(Abstract):
电网实时复杂的运行方式使得传统的定值校核方法存在某些特定情况下定值性能降低的情况;定值采用县调计算、地调复核的应用模式,地县间交界的定值性能需要有一定的手段进行评估。为了解决上述问题,研究了基于地县一体化继电保护定值在线校核系统实现方案。在介绍地县一体化继电保护定值在线校核系统功能体系和定值在线校核数据源获取的基础上,提出了地县一体化交界定值在线校核的策略,重点介绍了地县交界面的智能识别、校核原则设计以及校核原则的智能选择。以宁波电网为例,验证了在线校核系统的正确性及实用性。
The real-time and complicated operation mode of power grid lowers setting performance of setting value check method in particular situations. The setting value is calculated by county-level dispatch and checked by prefecture-level dispatch, and the prefectural-county setting performance needs some method to evaluate. To solve problems above, the paper investigates implementation scheme of online check system of integrated prefecture-county relay protection setting value. On the basis of introducing functional system of online check system of integrated prefecture-county relay protection setting value and access of online check data source, the paper presents a strategy of integrated prefecture-county online setting value check and emphatically introduces intelligent identification of prefecture-county interface, layout and intelligent choosing of check principles. Taking Ningbo power grid as an example, the paper verifies correctness and practicality of online check system.
关键词(KeyWords):
继电保护;在线校核;一体化;交界面
relay protection;online check;integration;interface
基金项目(Foundation):
作者(Author):
王祎,胡铁军,范黎敏,李雪冬,郑朋
WANG Yi,HU Tiejun,FAN Limin,LI Xuedong,ZHENG Peng
DOI: 10.19585/j.zjdl.2015.05.006
参考文献(References):
- [1]吕颖,张伯明.基于集群计算机的保护定值在线校核[J].电力系统自动化,2007,31(14):12-16.
- [2]陶佳燕,李银红,石东源,等.EMS与继电保护定值校核系统实时数据匹配新方法[J].电力系统自动化,2012,36(10):79-84.
- [3]张海翔,吕飞鹏,廖小君.一种继电保护定值在线校核评估方法[J].电力系统自动化,2013,37(3):98-103.
- [4]王晓梅.试析电力系统继电保护定值的在线校核[J].科技专论,2013(17):315-316.
- [5]蒙亮,黄超,陈金富.基于EMS的继电保护智能在线校核系统[J].广西电力,2012,35(2):20-23.
- [6]崔家佩,孟庆炎,陈水芳,等,电力系统继电保护与安全自动装置整定计算[M].北京:中国电力出版社,1993.