1000MW机组精确控制加氧处理技术的应用Application of Accurate Control of Oxygenated Feedwater Treatment in 1000 MW Units
施国忠,刘春红
SHI Guozhong,LIU Chunhong
摘要(Abstract):
为解决锅炉给水系统流动加速腐蚀的问题,对1000 MW机组锅炉采用了精确控制加氧技术,使给水中铁的含量基本控制在1μg/L以下,省煤器结垢速率为111.9 g/(m2·a),远远小于未加氧机组省煤器结垢速率,有效防止了水冷壁节流孔圈的堵塞,保证了机组的安全经济运行。
For handling flow accelerated corrosion of boiler feedwater system, accurate control of oxygenated feedwater is applied in boilers of 1000 MW units to keep iron content in the feedwater below 1 μg/L. The scaling rate of economizer is 111.9 g/(m2·a), which is far lower than that of economizer without oxygenation.Therefore, blockage in throttle orifice of water wall is prevented and safe and economical operation of units is guaranteed.
关键词(KeyWords):
1000 MW;超超临界机组;精确控制;加氧处理;结垢速率
1000 MW;ultra-supercritical units;accurate control;oxygenation;scaling rate
基金项目(Foundation):
作者(Author):
施国忠,刘春红
SHI Guozhong,LIU Chunhong
DOI: 10.19585/j.zjdl.2014.11.016
参考文献(References):
- [1]DL/T 805.4-2004火电厂汽水化学导则第4部份:锅炉给水处理[S].北京:中国电力出版社,2004.
- [2]IRMA DEDEKIND,DENIS ASPDEN,KEN J GALT,et al.Oxygenated feedwater treatment at the world′s largest fossil fired power plant-beware of the pitfalls[J].Power Plant Chemistry,2001,3(11):32-34.
- [3]ALEXANDER Y SUPERFIN,PRABHAT KUMAR SINHA.Alternative Boiler feedwater treatment by using the oxygenated technique[S].
- [4]何辉纯.重视水流加速腐蚀(FAC)的危害[C]//第六届全国电厂化学学术研讨会论文集.2000.
- [5]DL/T 805.1-2011火电厂汽水化学导则第1部份:直流锅炉给水加氧处理导则[S].北京:中国电力出版社,2011.