9FA燃机停机后缸温异常分析
Analysis of Cylinder Temperature Anomalies after Shutdown of 9FA Gas Turbine

潘小丰,杨金星
PAN Xiaofeng,YANG Jingxing

摘要(Abstract):

针对某9FA燃机停机后缸温下降速度异常增大的问题,分析异常现象并查找原因,通过更换中压并汽阀成功解决了此重大缺陷,可为类似机组的缸温异常分析提供参考。
Aiming at the increased lowering speed of cylinder temperature of 9 FA gas turbine after shutdown,the paper analyzes the abnormity and detects the reasons. The defect is eliminated by replacement of mediumpressure steam converging valve, which can be referenced for temperature abnormity analysis of similar steam turbines.

关键词(KeyWords): 9FA燃机;高压缸;缸温异常
9FA gas turbine;high pressure cylinder;cylinder temperature abnormity

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 潘小丰,杨金星
PAN Xiaofeng,YANG Jingxing

DOI: 10.19585/j.zjdl.201711015