GIS断路器智能汇控系统研究与应用Research and Application of an Intelligent Control System of GIS Circuit Breaker
戚宣威,王松,徐华,陈孝信,韩松杰,刘志祥
QI Xuanwei,WANG Song,XU Hua,CHEN Xiaoxin,HAU Songjie,LIU Zhixiang
摘要(Abstract):
针对现有断路器汇控系统存在设备可靠性低、调试运维困难、感知连接受限等问题,提出一种GIS断路器汇控系统的智能化、数字化升级方案。基于一、二次融合理念,采用高防护数字设备重构断路器汇控设备形态。该断路器智能汇控系统通过二次回路板件化实现断路器汇控回路的集成;采用软件逻辑实现三相不一致、防跳和储能电机过流等保护功能;应用数字化采集设备和智能变电站网络,实现断路器的状态感知、远方操作和联闭锁等功能。现场应用结果表明,所提GIS断路器智能汇控系统有效提升了断路器的运行可靠性及对设备的感知能力。
Given poor reliability, difficulty in commissioning, operation and maintenance, and constrained sensing connection of control system of the circuit breaker, the paper proposes an intelligent and digital scheme for control system of the GIS circuit breaker. Base on the concept of the integration of the primary and secondary systems, the control system of the circuit breaker is reconstructed by the digital device with high protection level. By panel-based secondary circuit, the intelligent control system of circuit breaker enables control circuit integration of circuit breaker. The protection functions, including the three-phase inconsistency, anti-tripping, and over-current protection of the storage motor, are carried out by the software. The condition monitoring, remote operation, and interlock are realized by the digital acquisition device and the intelligent substation network. The on-site application shows that this new GIS circuit breaker control system can effectively improve the operation reliability of the circuit breaker and the perception of the equipment.
关键词(KeyWords):
断路器;汇控系统;智能化;数字化;继电保护
circuit breaker;control system;intelligent;digital;relay protection
基金项目(Foundation): 国网浙江省电力有限公司科技项目(5211DS190029)
作者(Author):
戚宣威,王松,徐华,陈孝信,韩松杰,刘志祥
QI Xuanwei,WANG Song,XU Hua,CHEN Xiaoxin,HAU Songjie,LIU Zhixiang
DOI: 10.19585/j.zjdl.202108011
参考文献(References):
- [1]赵颖博.变电站微机保护断路器控制回路的改进[J].电气应用,2009,28(13):56-58.
- [2]周国伟,董建新,肖珊珊,等.高压断路器弹簧操动机构典型故障应力分析[J].浙江电力,2018,37(12):93-99.
- [3]裘鹏,黄晓明,王一,等.高压直流断路器在舟山柔直工程中的应用[J].高电压技术,2018,44(2):403-408.
- [4]吴健儿,何建,金李鸣.高压开关设备在浙江电力系统中的运行状况[J].电力设备,2007(3):111-113.
- [5]朱韬析,史志鸿,郭卫明,等.断路器操作箱和就地操作机构内合闸回路的配合问题[J].电力系统保护与控制,2010,38(8):115-119.
- [6]刘永兴.断路器操作回路中防跳继电器的选择[J].浙江电力,2008,27(4):73-75.
- [7]王洪俭,陈刚,汤金兴.高压断路器防跳回路实用化设计研究[J].浙江电力,2015,34(1):34-36.
- [8]郑建梓,陈东海.3/2断路器接线的保护死区分析[J].浙江电力,2007,26(3):54-56.
- [9]范江东.装设发电机出口断路器优越性的分析[J].浙江电力,2002,21(3):33-37.
- [10]李聪,周建平,万书亭.基于分合闸线圈电流特征的高压断路器机械故障诊断[J].浙江电力,2019,38(1):98-103.
- [11]方磊,吴建伟,周行,等.一起直流回路故障引起的断路器误动作分析[J].华东电力,2013,41(8):1699-1701.
- [12]丁文俊,林建钦,王正国.二起断路器遭受雷击损坏的事故分析[J].浙江电力,2009,28(3):69-71.
- [13]李建新.断路器线圈保护功能设计与实现[J].内蒙古电力技术,2019,37(1):64-67.