燃机余热锅炉过热器鳍片管变形原因分析
Cause Analysis on Finned Tube Deformation of Exhaust Heat Boiler Superheater of Combustion Engine

项建伟
XIANG Jianwei

摘要(Abstract):

介绍了燃机余热锅炉过热器结构布置,分析过热器鳍片管变形的可能原因,并对分析结果进行检查和检验,得出最终的诊断结果。
The paper introduces structural arrangement of exhaust heat boiler of combustion engine and analyzes possible reasons of finned tube deformation; furthermore, it inspects and checks the analysis results and concludes a final diagnosis result.