基于分段非线性函数的无功补偿经济性模型研究Study on Economic Model of Reactive Power Compensation Based on Piecewise Nonlinear Function
张文军,唐鸣,何鹤,吴颖
ZHANG Wenjun,TONG Ming,HE He,WU Ying
摘要(Abstract):
高压用户由于用电容量大,其功率因数的高低对供用电设备的容量利用率以及末端电压质量有着重要影响。为防止因用电功率因数不合格而缴纳力率调整电费,用户需合理安装无功补偿设备,提高用电功率因数。以电网公司对用户力率调整电费的计算参数为基础,通过对力率考核标准表进行分段非线性拟合,建立不同类型用户的无功补偿经济性模型,为用户合理投资无功补偿装置,降低用电成本提供参考。最后通过案例,对该模型进行了验证。
Because of the big electric capacity of high voltage power users, the power factor has great influence on the capacity utilization of power supply and consumption equipment and the terminal voltage quality.The power users should install reactive power compensation equipment appropriately to raise the power factor to avoid paying power factor regulating tariff due to the unqualified power factor. This paper, based on the calculation parameter of power factor regulating tariff and fitting the assessment standard of power factor with piecewise nonlinear function, establishes an economic model of reactive power compensation for different kinds of power users to provide reference for investing reactive power compensation equipment reasonably and reducing electricity cost for power users. At last, the model is verified by cases.
关键词(KeyWords):
无功补偿;功率因数;经济性;投资收益;变压器;损耗
reactive power compensation;power factor;economical efficiency;investment return;transformer;loss
基金项目(Foundation):
作者(Author):
张文军,唐鸣,何鹤,吴颖
ZHANG Wenjun,TONG Ming,HE He,WU Ying
DOI: 10.19585/j.zjdl.201712003
参考文献(References):
- [1]RUMIN LIU,LINGZHI YANG,HAIMING LIU.Analysis on the Application of Reactive Power Compensation Technology in Electrical Automation[J].Conference Proceedings Citaion Index,2015(2):118-121.
- [2]XQ BAN,X CHEN.Application Research on Reactive Power Compensation Technology in Electrical.Automation[J].Times gricultural Machinery,2015(2):118-121.
- [3]伍小杰,白玥.动态无功功率补偿研究的现状和展望[J].煤矿自动化,2000(5):19-21.
- [4]郝东勤.配电变压器低压无功补偿技术[J].陕西煤炭,2008(1):100-101.
- [5]金治乾.论低压无功功率补偿[J].包钢科技,2008,34(1):91-93.
- [6]陈勇.配电网10 k V电力线路无功补偿方法探讨[J].安徽电力,2015,32(2):14-17.
- [7]任丕德,刘发友,周胜军.动态无功补偿技术的应用现状[J].电网技术,2004,28(23):81-83.
- [8]何一浩,王树民.TSC动态无功补偿技术述评[J].中国电力,2004,37(10):22-26.
- [9]苏玲,宋珊,陈建业.静止无功补偿器(SVC)应用的最新进展[J].电网技术,2004,8(1):44-49.
- [10]戴晓亮.无功补偿技术在配电网中的应用[J].电网技术,1999,23(6):11-14.
- [11]顾国栋,黄奇峰,丁晓,等.电力用户功率因数考核方法优化方案研究[J].电网技术,2016,40(8):2477-2483.
- [12]戴彦,倪以信,文福拴,等.电力市场下的无功电价研究[J].电力系统自动化,2000(3):9-14.
- [13]袁佳歆,陈柏超,万黎,等.利用配电网静止无功补偿器改善配电网电能质量的方法[J].电网技术,2004,28(19):81-84.
- [14]袁佳歆,陈柏超,万黎,等.一种低压系统无功补偿器的研究[J].电力自动化设备,2004,24(3):69-71.
- [15]孙元章,王志芳,卢强.静止无功补偿器对电压稳定性的影响[J].中国电机工程学报,1997,17(6):373-376.
- [16]卜京,江宁强.计及谐波抑制的不对称负荷动态无功补偿方法[J].电网技术,2010,34(7):70-74.
- [17]李晨霞.基于负荷模型分析的电力系统电压稳定性研究[D].成都:西南交通大学,2009.
- [18]卢勇,李盛林,卢志强.电力系统无功补偿点的确定及其补偿方法[J].电力电容器,2006(2):14-19.
- [19]董云龙,吴杰,王念春,等.无功补偿技术综述[J].节能,2003(9):13-19.
- [20]陶骏,刘正之,许家治.基于电流调制的高功率动态静止无功补偿装置[J].电力系统自动化,2000(19):16-20.
- [21]季敏剑,周武.基于遗传算法的无功优化配置[J].浙江电力,2015,34(9):15-18.
- [22]何锋,章建华,沈丽雯,等.公变低压智能无功分散补偿装置的配置与应用[J].浙江电力,2016,35(3):18-21.
- [23]陆丹丹,夏红光,钟宇军,等.春节低负荷时期电网无功倒送问题的分析与应对[J].浙江电力,2017,36(4):27-30.