300MW机组锅炉MFT关键原因分析与现场改造措施研究Cause Analysis on MFT of a 300MW Boiler and Research on Field Transformation Measures
吴献锋,李德波,冯永新,周杰联,李建波
WU Xianfeng,LI Debo,FENG Yongxin,ZHOU Jielian,LI Jianbo
摘要(Abstract):
针对某发电厂发生MFT事件,从引风机电流、净烟气压力等方面进行了深入分析,在烟囱入口烟气挡板门开、关状态不清楚的情况下,找到了锅炉MFT事件的原因,主要结论如下:由于机组运行期间,烟囱入口烟气挡板门处于近乎关闭状态,导致烟道憋压,引风机运行工况点处于失速区,引起引风机喘振,最终导致MFT,建议将烟囱位置挡板门状态接入DCS系统,完善锅炉MFT后机组启动运行规程。
In view of the MFT(main fuel trip) event in a power plant, this paper makes a thorough analysis from the aspects of the induced fan current and the net flue gas pressure. Under the condition of unclear opening and closing of the flue gas baffle door at the entrance of the chimney, the causes of MFT are detected and main conclusions are as follows: during the operation of the unit, the flue gas baffle door at the chimney entrance is in a close state, which results in the flue shutoff pressure, and the running point of the induced fan is in the stall area, which leads to surge of the induced fan and MFT. It is suggested that the chimney position baffle door state be connected to the DCS system to improve the operation rules of the unit after MFT.
关键词(KeyWords):
MFT;引风机;喘振;净烟气压力
MFT;IDF;surge;net flue gas pressure
基金项目(Foundation): 国家自然科学基金重点项目(51376161)
作者(Author):
吴献锋,李德波,冯永新,周杰联,李建波
WU Xianfeng,LI Debo,FENG Yongxin,ZHOU Jielian,LI Jianbo
DOI: 10.19585/j.zjdl.201802014
参考文献(References):
- [1]侯剑雄,曾祥卓,李永秋.600 MW机组锅炉MFT动作原因分析及逻辑优化[J].广西电力,2016,39(5):16-20.
- [2]于国强,吕佳,高绥强.660 MW超超临界机组MFT时炉膛压力控制策略优化[J].江苏电机工程,2010,29(4):65-66.
- [3]徐冰.660 MW超临界机组MFT误动作事故分析及系统优化[J].安徽电子信息职业技术学院学报,2012,11(62):17-19.
- [4]苗长信,刘志敏,李志浩.某135 MW煤粉锅炉的一次异常MFT分析[J].山东电力技术,2005(3):53-55.
- [5]苗长信,姚常青.某600 MW机组锅炉异常MFT分析[J].电力建设,2008,29(8):81-83.
- [6]李德波,沈跃良,邓剑华,等.OPCC型旋流燃烧器大面积烧损的关键原因及改造措施[J].动力工程学报,2013,33(6):43-436.
- [7]李德波,沈跃良,徐齐胜,等.运用燃烧数值模拟分析某台660 MW超临界锅炉旋流燃烧器喷口烧损事故[J].机械工程学报,2013,49(16):121-130.
- [8]李德波,徐齐胜,李方勇,等.对冲旋流燃烧煤粉锅炉高温腐蚀现场试验与改造的数值模拟研究[J].广东电力,2015,28(11):6-12.
- [9]李德波,狄万丰.三合一引风机在1 045 MW火电机组中的应用[J].发电设备,2013,27(5):311-315.
- [10]李德波,徐齐胜,沈跃良,等.660 MW四角切圆锅炉低氮改造后变磨煤机组合方式下燃烧特性数值模拟[J].动力工程学报,2015,35(2):89-95.
- [11]李德波,狄万丰,李鑫,等.1 045 MW超超临界贫煤锅炉燃用高挥发分烟煤的燃烧调整研究及工程实践[J].热能动力工程,2016,31(1):117-123.
- [12]李德波,曾庭华,廖永进,等.燃煤机组SCR脱硝系统近零排放下热工控制研究与工程实践[J].动力工程学报,2017,37(7):569-576.
- [13]陈勤根,茅建波,应明良.某300 MW机组锅炉低氮燃烧器改造后再热汽温偏差大原因分析及调整[J].浙江电力,2016,35(3):42-45.
- [14]章良利,李敏,赵敏,等.对冲燃烧锅炉低氮燃烧器改造后煤种适应性试验研究[J].浙江电力,2016,35(11):37-41.
- [15]卢红书.300 MW机组锅炉燃烧系统低氮改造与效果分析[J].浙江电力,2015,34(1):37-40.