基于波形相似度的配电网故障选线新方法A New Method of Fault Line Selection in Distribution Network Based on Waveform Similarity
俞晨昊,王春蘅,陈中颖,司强,罗维真,姚毅杰
YU Chenhao,WANG Chunheng,CHEN Zhongying,SI Qiang,LUO Weizhen,YAO Yijie
摘要(Abstract):
小电流接地方式在配电网中应用广泛,传统的利用稳态电流进行故障选线与定位的方法局限性很大。通过研究配电网单相接地时的暂态电流信号,发现故障线路与健全线路的波形特征差别很大。提出利用各线路之间波形相关系数的选线方法,根据各条健全线路间相关系数接近、而故障线路与健全线路相关系数相差较大的特点,筛选出故障线路。仿真结果表明,该方法简单实用,定位准确,且不易受到外界因素干扰。
Small current grounding is widely used in the distribution network. The traditional use of steadystate current for fault line selection and positioning is very limited. By study the transient current signal of distribution network in the case of single phase grounding, it is found that fault lines and non-fault lines differ greatly in waveform characteristics. The paper proposes a line selection method based on waveform correlation coefficient to select fault lines in accordance with the fact that the correlation coefficients of non-fault lines are almost the same while those of fault lines and non-fault lines differs greatly. As the simulation shows, the method is simple and practical, and is accurate in positioning and not easily disturbed by external factors.
关键词(KeyWords):
小电流接地;暂态电流信号;相似度;相关系数
small current grounding;transient current signal;similarity;correlation coefficient
基金项目(Foundation): 南京工程学院大学生科技创新项目(TB201816031)
作者(Author):
俞晨昊,王春蘅,陈中颖,司强,罗维真,姚毅杰
YU Chenhao,WANG Chunheng,CHEN Zhongying,SI Qiang,LUO Weizhen,YAO Yijie
DOI: 10.19585/j.zjdl.201807014
参考文献(References):
- [1]韩笑.电力系统继电保护[M]..北京:机械工业出版社,2015.
- [2]王清亮.单相接地故障分析与选线技术[M].北京:中国电力出版社,2013.
- [3]薛永端,李天友,李伟新,等.小电流接地故障暂态分析及区段定位新方法[J].电力系统自动化,2014,38(23):101-106.
- [4]庞清乐,陈生银.基于人工免疫算法的小电流接地故障选线[J].电力系统保护与控制,2009,37(24):27-31.
- [5]刘谋海,王媛媛,曾祥君,等.基于暂态相电流特征分析的故障选线新方法[J].电力系统及其自动化,2017,29(1):30-36.
- [6]孙波,孙同景,薛永端,等.基于暂态信息的小电流接地故障区段定位[J].电力系统自动化,2008,32(3):52-55.
- [7]倪管魁,鲍海,张利,等.基于零序电流突变的配电网单相故障带电定位判据[J].中国电机工程学报,2010,30(31):118-122.
- [8]郑顾平,张利,姜超,等.中性点不接地系统单相接地故障区段在线定位[J].电力系统自动化,2013,37(3):110-115.
- [9]任建文,孙文武,周明,等.基于数学形态学的配电网单相接地故障暂态选线算法[J].电力系统自动化,2007,30(1):65-70.
- [10]马士聪,徐丙垠,高厚磊,等.检测暂态零模电流相关性的小电流接地故障定位方法[J].电力系统自动化,2008,32(7):45-51.
- [11]张新慧,薛永端,潘贞存,等.单相接地故障零模暂态特征的仿真分析[J].电力自动化设备,2007,27(12):39-43.
- [12]陈维贤,陈禾.配电网中电压互感器消谐、单相消弧和单相永久性故障切线问题的解决方案[J].高电压技术,2012,38(4):776-781.