某330 MW汽轮发电机组异常振动分析与诊断Analysis and Diagnosis of Abnormal Vibration for a 330 MW Steam Turbine Generator Unit
赵卫正,童小忠,陈杰
ZHAO Weizheng,TONG Xiaozhong,CHEN Jie
摘要(Abstract):
某发电厂机组调停后开机,带负荷过程中5号轴振爬升导致跳机,诊断为动静碰磨。对轴振变化量进行了分析,判断碰磨位置可能为低发联轴器。根据动静碰磨发生时振动同步分量爬升和非同步分量明显上升现象,进一步阐释了动静碰磨热弯曲和力冲击效应。停机检修时发现低压联轴器有明显的划痕,检查结果表明对此次振动的分析与诊断是正确的,为类似的故障问题提供了诊断思路。
After a scheduled unit shutdown in a power plant, shaft vibration of bearing No.5 increased abnormally during operation and finally led to unit tripping, which turned out to be rubbing between stationary and movable parts. Firstly vibration variation was analyzed and determined that the rubbing occurred probably at the shafting coupling device. As the synchronous component and asynchronous component of vibration increased significantly in the case of rubbing between stationary and movable parts, the paper further expounds thermal bending and force impact effect from the rubbing. During shutdown and maintenance, it is found that there were obvious scratches on the shafting coupling device, which means the vibration analysis and diagnosis is correct, and can provide diagnosis idea for handing similar problems.
关键词(KeyWords):
汽轮发电机组;动静碰磨;振动;故障诊断
steam turbine generator unit;rubbing between movable and stationary parts;vibration;fault diagnosis
基金项目(Foundation):
作者(Author):
赵卫正,童小忠,陈杰
ZHAO Weizheng,TONG Xiaozhong,CHEN Jie
DOI: 10.19585/j.zjdl.201804016
参考文献(References):
- [1]李卫军,吴文健,蔡文方.某台350 MW双水内冷汽轮发电机组振动异常处理及分析[J].浙江电力,2017,36(1):47-49.
- [2]马思聪,蔡文方.发电机转子振动故障的诊断与处理[J].浙江电力,2017,36(1):64-67.
- [3]赵卫正,陈杰.660 MW超超临界机组振动原因分析与处理[J].浙江电力,2014,33(11):49-51.
- [4]张学延.汽轮发电机组振动诊断[M].北京:中国电力出版社,2008:46.
- [5]徐百成,李卫军,吴文健,等.9FA燃气轮机高中压转子碰摩振动的分析与处理[J].浙江电力,2014,33(12):38-40.
- [6]应光耀,童小忠,吴文健.9F联合循环机组严重碰摩诊断分析及处理[J].汽轮机技术,2010,52(1):74-76.
- [7]陆颂元,吴峥峰.汽轮发电机组振动故障诊断及案例[M].北京:中国电力出版社,2016.
- [8]杨建刚.旋转机械振动分析与工程应用[M].北京:中国电力出版社,2007.
- [9]陆颂元,童小忠.汽轮机组现场动静碰磨故障的振动特征及分析诊断方法[J].动力工程,2002,22(6):2020-2024.
- [10]林琳,黄保志.某汽轮机轴振监测系统故障分析处理[J].广东电力,2017,30(9):33-36.
- [11]杨毅,高庆水,张楚,等.CPR1000技术核电机组高频振动故障诊断与处理[J].广东电力,2016,29(1):22-26.
- [12]马运翔,薛江涛,刘晓锋,等.1 000 MW二次再热超超临界汽轮机组摩擦故障分析[J].电力工程技术,2017,36(1):113-116.
- [13]黄松涛.一起发电机转子匝间短路故障的分析和处理[J].江苏电机工程,2016,35(2):87-88.
- [14]李勇,张宝东.330 MW机组凝汽器真空低原因分析及处理[J].浙江水利水电学院学报,2017,29(3):72-75.