浙江电力

2014, v.33;No.217(05) 17-21

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

10kV配电网无功补偿的仿真优化方法研究
Research on Simulation Optimization Method of Reactive Power Compensation for 10kV Distribution Network

宓天洲,李志,毛航银
MI Tianzhou,LI Zhi,MAO Hangyin

摘要(Abstract):

研究配电线路柱上无功补偿装置电容器分组方式,根据某海岛配电网的无功状况,综合考虑投切精度和经济因素,对柱上无功补偿装置的电容器容量分组进行优化,采用SIMULINK仿真对优化后的分组进行仿真分析,最终形成了一种基于分组优化的投切方案。
The capacitor grouping methods of pole-mounted reactive power compensation device on distribution lines are investigated in this paper. According to reactive power status of an island distribution network and in consideration of switching accuracy and economic factors, this paper optimizes capacitor capacity grouping of pole-mounted reactive power compensation device, and it simulates and analyzes the optimized grouping using SIMULINK simulation. Finally, a switching scheme based on grouping optimization is formed.

关键词(KeyWords): 配电网;柱上无功补偿;无功;分组;优化
power distribution network;pole-mounted reactive power compensation;reactive power;grouping;optimization