600 MW机组电动给水泵变频改造及经济性分析Frequency Conversion Renovation of Electric Feedwater Pump of 600 MW Unit and the Economic Efficiency Analysis
周正道,包伟伟,秦英武,高德民,宁辉
ZHOU Zhengdao,BAO Weiwei,QIN Yingwu,GAO Demin,NING Hui
摘要(Abstract):
电动给水泵是燃煤发电机组的主要辅机设备,采用液力耦合器调速技术的电动给水泵组节能空间较大。以国内首台600 MW亚临界直接空冷机组电动给水泵组的变频改造为例,论述机组的运行现状及变频改造情况,对改造前后的经济性进行全面分析比较,结果表明:变频改造后,电动给水泵组的效率平均提高约13个百分点,机组加权厂用电率下降0.79个百分点,经济效益显著。
Electric feedwater pump is a key auxiliary device of coal-fired generating units, and there is much energy-saving room for electric feedwater pumps with hydrokinetic coupling techniques. Based on the frequency conversion renovation of electric feedwater pumps of the first 600 MW subcritical direct air cooling units in China, the paper elaborates on the units operation status and frequency conversion renovation and compares the economic efficiencies before and after the renovation. The result shows that after the renovation the efficiency of the electric feedwater increases by 13% on average and the weighting auxiliary power consumption rate decreases by 0.79%, bringing about significant economic benefit.
关键词(KeyWords):
600 MW机组;电动给水泵;高压大功率变频器;液力耦合器;经济性
600 MW unit;electric boiler feedwater pump;high-voltage high-power frequency transformer;hydraulic coupling;economic efficiency
基金项目(Foundation):
作者(Author):
周正道,包伟伟,秦英武,高德民,宁辉
ZHOU Zhengdao,BAO Weiwei,QIN Yingwu,GAO Demin,NING Hui
DOI: 10.19585/j.zjdl.202006011
参考文献(References):
- [1]付怀仁,包伟伟,张敏.当前主流供热改造技术的灵活性及经济性分析[J].热力透平,2019,48(2):99-104.
- [2]包伟伟.1 000 MW超超临界机组增设0号高压加热器经济性分析[J].发电设备,2015,29(3):172-175.
- [3]包伟伟,康剑南,赫广迅,等.大型汽轮发电机组可调节回热抽汽设计思想[J].热力透平,2015,44(3):161-165.
- [4]包伟伟.大型汽轮发电机组变负荷工况经济性分析[J].热力透平,2016,45(4):279-283.
- [5]张宝.凝结水泵变频改造调试与节能潜力挖掘[J].浙江电力,2008,27(5):34-36.
- [6]曹锐杰.300 MW机组电动给水泵变频改造应用[J].山西电力,2015(2):62-65.
- [7]张彩,张宝.凝结水泵变频改造的问题与对策[J].电力科学与工程,2013,29(1):74-78.
- [8]张吕华.台州发电厂送风机选用YOTCS调速型液力偶合器选型计算的参考[J].浙江电力,1998,17(6):31-34.
- [9]张宝,樊印龙,吴文健,等.凝结水泵变速运行参数的定量计算[J].动力工程学报,2010,30(9):684-688.
- [10]谢龙.塔山电厂2号机组电动给水泵变频调速系统的改造及效益[J].机电信息,2017(12):72-73.
- [11]秦英武,高德民,程明,等.大型火力发电机组电动给水泵节能改造应用及研究(上)[J].变频器世界,2017(12):71-74.
- [12]秦英武,高德民,程明,等.大型火力发电机组电动给水泵节能改造应用及研究(下)[J].变频器世界,2018(1):86-90.
- [13]姚大春,秦英武,张博,等.“增速型液力偶合器的变频调速装置”在600 MW机组上的应用[J].变频器世界,2019(8):80-82.
- [14]包伟伟,孙桂军,李贺莱,等.600 MW超临界空冷机组双背压低真空供热改造[J].热力透平,2017,46(4):252-257.
- [15]包伟伟,杨宇,康剑南,等.1 350 MW超超临界二次再热机组总体设计及经济性分析[J].汽轮机技术,2017,59(1):21-25.
- [16]王川川,李金霞,禹贯省,等.1 000 MW超超临界机组凝结水泵变频改造[J].内蒙古电力技术,2019,37(2):84-87.
- [17]陈统钱,杨建明.660 MW机组凝结水泵变频运行的振动分析与处理[J].发电技术,2019(S1):68-72.
- 600 MW机组
- 电动给水泵
- 高压大功率变频器
- 液力耦合器
- 经济性
600 MW unit - electric boiler feedwater pump
- high-voltage high-power frequency transformer
- hydraulic coupling
- economic efficiency