浙江电力

2010, v.29;No.175(11) 43-45+48

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

600MW机组励磁机转子振动分析与处理
Analysis and Treatment of Exciter Shaft Vibration for 600 MW Unit

刘奇洪
LIU Qi-hong(Shenhua Zhejiang Guohua Zheneng Power Generation Co.

摘要(Abstract):

宁海发电厂1号机励磁机转子振动曾经严重超标,综合分析振动超标的各种原因,得出垫铁绝缘垫片老化引起的结论。通过更换处理彻底解决了励磁机转子振动异常的问题,可为其它电厂处理类似问题提供借鉴。
Shaft vibration of exciter of Unit 1 in Ninghai Power Plant used to be out of range.It concludes that it is resulted from the aged insulation spacer of shim plate through comprehensive analysis of this problem.As a result,it is solved thoroughly with replacement and can serve as a reference for solutions to similar problems in other power plants.

关键词(KeyWords): 600MW机组;励磁机;轴振;绝缘垫片;老化
600 MW unit;exciter;shaft vibration;insulation spacer;aging

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 刘奇洪
LIU Qi-hong(Shenhua Zhejiang Guohua Zheneng Power Generation Co.

DOI: 10.19585/j.zjdl.2010.11.013