计量装置状态监控系统的开发及应用Exploitation and Application of MOCMS
李均毅,董寒宇,史田莘
LI Jun-yi, DONG Han-yu, SHI Tian-xin(Huzhou Electric Power Bureau
摘要(Abstract):
介绍了计量装置状态监控系统(MOCMS)的原理和功能,根据实际的误差数据,运用控制图法对运行中的电子式电能表的误差特性进行分析。由于表计良好的误差特性以及MOCMS的应用,使电能表校验周期延长成为了可能。
The paper introduces the principle and function of Metering-device Operation Condition Monitor System(MOCMS), and analyzes the error characteristics of electronic watt-hour meter in operation by using control chart method based on real error dates. After researching: because of the stable error characteristics of watt-hour meter and the application of MOCMS, it is possible to prolong error calibration periodicity.
关键词(KeyWords):
MOCMS;控制图法;校验周期
MOCMS; control chart method; calibration periodicity
基金项目(Foundation):
作者(Author):
李均毅,董寒宇,史田莘
LI Jun-yi, DONG Han-yu, SHI Tian-xin(Huzhou Electric Power Bureau
DOI: 10.19585/j.zjdl.2009.03.016