浙江电力

2012, v.31;No.199(11) 82-84

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

9E燃机压气机防喘设备及其故障检修
Anti-surge Device for Air Compressor of 9E Gas Turbine and the Corrective Maintenance

方国民
FANG Guo-min(Taizhou Power Plant

摘要(Abstract):

在介绍9E燃气轮机压气机的喘振原理以及防喘措施的基础上,结合机组运行实际情况,对常见的旋转导叶动作滞缓、防喘放气阀打开延迟等防喘设备故障原因进行分析,并提出了处理措施。
On the basis of introducing principle of surge of air compressor of 9E gas turbine and anti-surge measures,the paper,in combination with the practical operation of units,analyzes causes for faults of antisurge devices such as slowness of rotating guide vane,delay in opening release valve and so on;it also puts forward disposals.

关键词(KeyWords): 9E燃气轮机;防喘设备;故障处理
9E gas turbine;anti-surge device;corrective maintenance

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 方国民
FANG Guo-min(Taizhou Power Plant

DOI: 10.19585/j.zjdl.2012.11.024