基于超高压线路参数估计的故障测距算法研究
Research on Fault Location Algorithm Based on EHV Transmission Line Parameter Estimation

宋艳,曾铁军,于旭东
SONG Yan,ZENG Tie-jun,YU Xu-dong(State Grid Electric Power Research Institute

摘要(Abstract):

提出一种基于线路参数估计的故障测距二分法。该方法基于线路分布参数模型,无需获得准确的线路阻抗参数,根据正序故障分量电压沿线分布规律,用二分法通过搜索迭代求取故障距离。这一方法理论上不受故障过渡电阻的影响,不必判断故障相别。MATLAB仿真结果表明此算法具有较高的测距精度。
Based on the distributed parameter model of power transmission line,a dichotomy algorithm for fault location is proposed in which the accurate value of the line parameters does not need to be known.According to the distribution regularity of positive sequence voltage along the transmission line and applying search method,it determines accurately the distance of fault point.In theory this algorithm is not affected by fault resistance and does not need fault phase identification.MATLAB simulation results show that the algorithm has high accuracy.

关键词(KeyWords): 故障测距;分布参数;参数估计;二分法
fault location;distributed parameter;line parameter estimation;dichotomy algorithm