电站热工优化控制平台汽温优化组件的开发应用Development and Application of the Steam Temperature Optimization Module on Power Plant Thermal Optimized-control Platform
陈波,孙耘,李泉,张永军,丁宁
CHEN Bo,SUN Yun,LI Quan,ZHANG Yong-jun,DING Ning(Z(P)EPC Electric Power Research Institute
摘要(Abstract):
目前大型火电机组的锅炉过热汽温和再热汽温控制仍采用常规的串级控制系统,当机组负荷变化时,汽温就偏离设定值8-10℃左右,超温很频繁。TOP(电站热工优化控制平台)系统的汽温优化组件采用现代控制理论进行设计,用系统内部状态来描述系统,实现闭环系统极点的任意配置,从而构成线性最优调节器;采用温度动态特性状态重构技术,获得具有较强稳定性和鲁棒性的控制系统,有效解决了汽温偏离设定值的问题。
At present,superheater steam temperature and reheater steam temperature control of large thermal generating units still adopts conventional cascade control system.In case the unit load changes,the steam temperature varies 8 to 10 centidegrees from the set value and there is frequent superheat.The design of steam temperature optimization module on the power plant thermal optimized-control platform employs modern control theory,and the system is described by its internal state to randomly configure poles of close-loop system,hence linear optimal adjuster is structured.Dynamic temperature characteristic restructuring technology is employed to make the control system more stable and robust,which solves the set value variation of steam temperature.
关键词(KeyWords):
TOP;汽温优化组件;控制;极点配置;状态重构
TOP;steam temperature optimization module;control;pole assignment;state restructuring
基金项目(Foundation):
作者(Author):
陈波,孙耘,李泉,张永军,丁宁
CHEN Bo,SUN Yun,LI Quan,ZHANG Yong-jun,DING Ning(Z(P)EPC Electric Power Research Institute
DOI: 10.19585/j.zjdl.2013.03.015
参考文献(References):
- 张长青,杨锋,孟祖浩,等.锅炉汽温控制状态反馈极点配置的两种简易设计方法[J].中国电机工程学报,2006,26(9):62-65.
- 陈一秀,陈永红.纯滞后系统的状态反馈优化设计方法[J].控制工程,2004,11(3):223-225.
- 李泉.超(超超)临界机组主汽温控制系统控制传递策略研究与应用[J].华东电力,2010,38(7):28-32.
- 陈小强,罗志浩,赵洪宇.两类超超临界1 000 MW直流锅炉中间点温度控制策略和效果分析[J].华东电力,2009,37(8):1418-1421.
- 李泉,朱北恒,孙耘,等.火电机组主汽温控制优化策略的研究[J].浙江电力,2010,29(3):26-29.
- 陈波,张永军,罗志浩.超临界机组汽温控制中减温水联控方式的研究与实现[J].电站系统工程,2010,26(4):54-56.