浙江电力

2012, v.31;No.191(03) 12-15

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

500kV变电站跨三档管母高层导线更换技术研究
Research on Replacement Technology of High Line Crossing Three Tubular Busbar Groups for 500 kV Substation

吴浩,杨杰,潘国跃,张汉荣
WU Hao,YANG Jie,PAN Guo-yue,ZHANG Han-rong(Zhejiang Electric Transmission and Transformation Engineering Co.

摘要(Abstract):

结合500 kV瓯海变技改工程,针对跨三档管母高层导线更换时停电时间短、作业范围窄等难点,在理论计算的基础上,提出了更换导线的技术方案,详细介绍了高层导线的拆除与安装过程,通过实践验证了技术方案的可行性,保证了更换导线施工的安全和质量。
Based on the 500 kV technical renovation project of Ouhai Substation,this paper presents a technical scheme for high line replacement based on theoretical calculation to deal with the difficulties of short-time outage,narrow operating range etc.for replacement of high line crossing three tubular busbar groups.It describes the processes of the removal and installation of the high line.The scheme proves to be feasible after practice and ensures replacement safety and quality.

关键词(KeyWords): 变电站;高层导线;张力;导线更换
substation;high line;tension;line replacement

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 吴浩,杨杰,潘国跃,张汉荣
WU Hao,YANG Jie,PAN Guo-yue,ZHANG Han-rong(Zhejiang Electric Transmission and Transformation Engineering Co.

DOI: 10.19585/j.zjdl.2012.03.004

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享