9FA燃机燃气压力低遮断原因分析及处理Cause Analysis and Treatment on Lower Gas Pressure Shutoff of 9FA Gas Turbine
丁建军,武海南,冯鹏飞
DING Jianjun,WU Hainan,FENG Penghui
摘要(Abstract):
介绍了一起9FA联合循环机组在运行中因天然气压力低造成机组遮断的事故,认为燃气轮机供气压力低是由于安全切断阀气动排空阀误开所致,而控制回路设计缺陷是排空阀误开的根本原因。对此,提出了有针对性的改造方案,为排空阀增加了1个控制电磁阀,与原控制电磁阀互为备用,2个电磁阀采取了巧妙的并联布置方式。该方案简单可靠,成本低,可复制性强,并对燃料气控制系统其他类似气动阀门进行了相同改造,从而确保机组长期安全运行。
This paper introduces a shutoff accident of 9FA combined cycle units due to low gas pressure in the operation. It is believed that the low gas pressure of the gas turbine is caused by mistaken switch-on of pneumatic exhaust valve of safety shutoff valve; however, design defect of control circuit fundamentally results in switch-on of the exhaust valve. Therefore, the paper accordingly presents a retrofit scheme: equipping an electromagnetic control valve on the exhaust valve as a spare part of the original one, and the two valves are paralleled in a subtle way. The scheme is simple, reliable and low in cost, and can be easily duplicated;besides, it reconstructs fuel gas control system and other pneumatic valves in a similar way to ensure long operation safety of the units.
关键词(KeyWords):
燃气轮机;天然气;电磁阀;遮断;技术改造;燃气压力低
gas turbine;natural gas;electromagnetic valve;shutoff;technological transformation;low gas pressure
基金项目(Foundation):
作者(Author):
丁建军,武海南,冯鹏飞
DING Jianjun,WU Hainan,FENG Penghui
DOI: 10.19585/j.zjdl.201706017
参考文献(References):
- [1]张东晓.大型燃气-蒸汽联合循环发电技术丛书设备及系统分册[M].北京:中国电力出版社,2009.
- [2]章素华.燃气轮机发电机组控制系统[M].北京:中国电力出版社,2013.
- [3]曹晓晖.浅谈燃机热工维护经验[C].中国电机工程学会燃机发电专委会年会论文集,2007.
- [4]郑培根.气动电磁阀综合性能测试系统的研究[D].杭州:浙江大学,2011.
- [5]WALKER S.Balding Site Improvements[C].Dubai:GE User Group Conference,2010.
- [6]陈学敏.工程中电磁阀的应用探讨[J].石油化工自动化,2009,45(4):58-61.
- [7]焦树建.燃气轮机与燃气-蒸汽联合循环装置[M].北京:中国电力出版社,2007.
- [8]广东惠州天然气发电有限公司.燃气-蒸汽联合循环发电设备与运行:机务分册[M].北京:机械工业出版社,2013.
- [9]刘小华.9FA燃料清吹系统问题分析和技术改进[J].价值工程,2015,34(2):32-33.
- [10]许平宝.9FA机组燃料清吹阀门动作故障分析与预防[J].燃气轮机技术,2012,25(2):59-63.