浙江电力

2012, v.31;No.195(07) 48-49

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

发电厂循泵房旋转滤网冲洗水泵选型分析
Selection Analysis for Rotary Filter Screen Wash-water Pumps in Circulating Water Pump House of Power Plant

刘建东,李明志
LIU Jian-dong,LI Ming-zhi(Datang Wushashan Power Generation Co.

摘要(Abstract):

发电厂循环水泵房旋转滤网的冲洗水泵通常为自吸立式长轴式,运行中故障率较高。经过分析与计算,将其改造为单级离心水泵,从冲洗水泵改造前后各参数的对比及稳定运行情况来看,冲洗水泵的改造效果良好。
The wash-water pumps for the rotary filter screens in the circulating water pump house of the power plant is usually vertical self-priming long shaft type.The failure rate is high in operation.Through the analysis and calculation,this paper transforms the pumps into single-stage centrifugal ones.The parameter comparison before and after the retrofit and stable operation show that the retrofit achieves great effect.

关键词(KeyWords): 冲洗水泵;立式离心泵;断轴;磨损
wash-water pump;vertical centrifugal pump;broken shaft;abrasion

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 刘建东,李明志
LIU Jian-dong,LI Ming-zhi(Datang Wushashan Power Generation Co.

DOI: 10.19585/j.zjdl.2012.07.016