简要介绍非晶合金干式变压器在配电网建设中的应用及其噪声产生的原因,并对噪声传播的方式进行分析,对降低非晶合金变压器噪声的方法进行了探索,提出通过减震器和消声器相结合的方式来降低非晶合金变压器噪声,实际应用表明噪声治理效果显著。
The paper briefly introduces application of amorphous alloy dry-type transformers in distribution networks and the noise causes; besides, it analyzes the noise transmitting modes and explores noise reduction method for amorphous alloy dry-type transformer. At last, this paper proposes a noise reduction method of using shock absorber and muffle, which turns out to be effective in noise treatment.
关键词(KeyWords):
配电网;非晶合金;干式变压器;噪音;降噪改造
distribution network;amorphous alloy;dry-type transformers;noise;noise reduction transformation