浙江电力

2016, v.35;No.248(12) 21-25

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

某1000 MW燃煤机组超低排放改造减排NOX的环境效益评价
Environmental Impact Assessment on NOX Emission Reduction of a 1000 MW Ultra-low Emission Coal-fired Unit

寿春晖,祁志福,陈彪,刘春红
SHOU Chunhui,QI Zhifu,CHENG Biao,LIU Chunhong

摘要(Abstract):

利用AERMOD模型对某1 000 MW燃煤机组改造前后排放NO_X在大气中的传输、扩散过程进行了模拟,定量计算了NO_X环境浓度及其分布情况。研究发现:通过超低排放改造项目削减NO_X排放,可使环境空气中NO_X最大落地浓度大量减少、占标率明显下降;各峰值分布区域污染物浓度降幅显著,各时段均值占标率大幅下降;全区域各时间段浓度值均降低、分布梯度变小。研究结果表明:火电行业通过"超低排放"进一步控制NO_X污染对环境影响正效益显著,发电厂周边环境空气质量得以整体大幅提升。
The diffusion and transmission in the atmosphere of NO_X emissions from a 1 000 MW coal-fired power plant is simulated by using AERMOD modeling system to calculate the ambient concentration and distribution of NO_X. The results show that the reduction of NO_Xby "ultra-low emission" transformation enables greatly reduction of maximum ground concentration in ambient air and decrease of the ratio to standard concentration; the pollutant concentration in peak distribution area decreases and the mean values to standard concentration at each time period are lowered greatly; the concentration value in the whole region at every time period decreases and the distribution gradient of NO_Xbecomes smaller. The research shows that further control of thermal power industry over NO_Xpollution by "ultra-low emission" has positive benefit on the environment, and the ambient air quality around the power plant is notably improved.

关键词(KeyWords): AERMOD;NOX;环境影响;火电厂;超低排放
AERMOD;NOX;environmental impact;thermal power plant;ultra-low emission

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 寿春晖,祁志福,陈彪,刘春红
SHOU Chunhui,QI Zhifu,CHENG Biao,LIU Chunhong

DOI: 10.19585/j.zjdl.2016.12.005

参考文献(References):