介绍了北仑发电厂二期工程3号发电机严密性试验的试验方法、计算方法及试验结果 ,通过对严密性试验漏气量计算公式、密封油中空气溶解度以及测量误差的深入分析 ,揭示了试验结果是正确的和可接受的。
The procedure,calculation method and results of generator air tightness test for unit 3 of Beilun power plant phase II project are introduced in this paper.The test results prove to be right and acceptable on the basis of deep analysis of air leakage formula,air solubility in seal oil and measuring error of air tightness test.