浙江电力

2011, v.30;No.188(12) 60-62

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

微油模式下机组冷态启动的低压缸差胀控制
Control of Differential Expansion for Low Pressure Cylinder During Cold Start of Units in Tiny-oil Mode

罗晶
LUO Jing(Taizhou Power Plant

摘要(Abstract):

分析了台州发电厂330 MW机组锅炉微油点火改造后冷态启动过程中低压缸正胀差偏大的原因,从多方面提出应对措施,通过实例分析验证了措施的有效性。
Through the cause analysis of excessive differential expansion of low pressure cylinder during cold start after tiny-oil ignition transformation of boiler for 330 MW units in Taizhou Power Plant,the countermeasures are put forward and its effectiveness is verified through example analysis.

关键词(KeyWords): 微油点火;冷态启动;低压差胀;安全性
tiny-oil ignition;cold start;low pressure differential expansion;security

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 罗晶
LUO Jing(Taizhou Power Plant

DOI: 10.19585/j.zjdl.2011.12.017