主汽阀故障造成汽轮机单侧进汽的判断与分析Judgment and Analysis on Unilateral Steam Admission of Steam Turbine Caused by Main Steam Valve
胡洲,吴文健,樊印龙,顾正皓,吴瑞康
HU Zhou,WU Wenjian,FAN Yinlong,GU Zhenhao,WU Ruikang
摘要(Abstract):
针对某600 MW机组在启动过程中出现的1号轴瓦温度偏高问题,对汽轮机进行转子汽流受力分析以及关阀、升负荷等一系列试验,检查分析后,判断出汽轮机的左侧进汽通流面积产生了变化,并据此判断对汽轮机左侧进汽通流区域有关阀门和管道等进行了检查,查明了导致1号轴瓦温度偏高的原因为1号高压主汽阀主阀蝶脱落,造成汽轮机单侧进汽。对主阀蝶脱落及相关问题进行了分析,并提供了运行建议。
Aiming at overheat of #1 bearing during startup of 600 MW units, the steam flow stress of rotor is analyzed, and test, check and analysis on valve shutdown and load rising are conducted, from which it is determined that inlet throughflow area at the left of steam turbine becomes changed. According to the judgment,the concerned valves and pipes at the left side of the turbine inlet throughflow area are inspected. It is found that overheat of #1 bearing is triggered by drop of main butterfly valve of #1 high-pressure main steam valve,which further causes unilateral admission. The paper analyzes main butterfly valve drop and relevant issues;besides, it puts forward suggestions on operation.
关键词(KeyWords):
600 MW;汽轮机;高压主汽阀;轴承温度;单侧进汽
600 MW;steam turbine;high-pressure main steam valve;bearing temperature;unilateral admission
基金项目(Foundation):
作者(Author):
胡洲,吴文健,樊印龙,顾正皓,吴瑞康
HU Zhou,WU Wenjian,FAN Yinlong,GU Zhenhao,WU Ruikang
DOI: 10.19585/j.zjdl.2015.09.014
参考文献(References):
- [1]陈华桂,秦惠敏,戴兴干.660 MW汽轮机轴瓦温度异常的分析与处理[J].江苏电机工程,2014,33(2):75-78.
- [2]张楚,刘石,冯永新,等.600 MW机组大修后瓦温高及异常振动分析与处理[J].广东电力,2013,26(11):114-118.
- [3]刘兴华,张春,张九栋,等.600 MW汽轮机瓦温高的原因分析[J].宁夏电力,2011(2):51-56.
- [4]向丽晖,庞亚宁.机组进汽方式对轴振瓦温的影响[J].华北电力技术,2007(2):48-51.
- [5]徐熙瑾,王学根,朱朝阳,等.改变阀门配汽特性降低主机轴承温度[J].汽轮机技术,2007,49(3):220-222.
- [6]李卫军,张宝,童小忠,等.汽轮机进汽方式切换时轴振与瓦温异常分析[J].汽轮机技术,2006,48(6):462-464.