振动法在变压器有载调压开关检测中的应用Application of Vibration Method in Testing of On-load Tap Changer of Transformer
钱峰,高继鸣,何肖军
QIAN Feng1,GAO Ji-ming1,HE Xiao-jun2(1.Shanghai Municipal Electric Power Company
摘要(Abstract):
介绍了有载调压变压器分接开关的振动法检测原理、检测系统、检测主要内容和关键技术,以某110 kV变电站2号主变压器的有载调压开关为例,对检测的信号进行了对比分析,指出可能存在的故障隐患,实践证明这类检测设备是有载调压变压器状态检测的有力工具。
This paper introduces principles of vibration method for tap changing switch testing of on-load tap changing transformer,testing system,testing items and key technologies.By taking on-load tap changer of main transformer No.2 in a 110 kV substation as an example,the testing signal is comparatively analyzed and the potential faults are presented.Practice showed that the vibration method turns out to be a power tool to detect the state of on-load tap-changing transformer.
关键词(KeyWords):
变压器;有载调压开关;振动法;检测
transformer;on-load tap-changing switch;vibration method;testing
基金项目(Foundation):
作者(Author):
钱峰,高继鸣,何肖军
QIAN Feng1,GAO Ji-ming1,HE Xiao-jun2(1.Shanghai Municipal Electric Power Company
DOI: 10.19585/j.zjdl.2013.03.005
参考文献(References):
- 张德明.有载分接开关国内现状及其发展动向[J].变压器,2000,37(1):36-39.
- 咸日常.变压器有载分接开关常见故障的综合判断与现场处理[J].高压电器,2002,38(5):49-51.
- P KANG,D BIRTWHISTLE.Application of Condition Monitoring and Diagnostic Techniques for on Load Tap Changers[C]//Australasian University Power Engineering Conference,1997.