基于供电可靠性量化分析的110kV电网典型接线方式选择
Determination of Representative Network Structures for 110 kV Power Networks Based on the Analysis of Reliability of Power Supplies

尹建兵,黄民翔,许诺
YIN Jian-bing 1,HUANG Min-xiang 2,XU Nuo 2(1.Hangzhou Municipal Electric Power Bureau

摘要(Abstract):

目前国内对110kV电网接线方式供电可靠性定量分析的研究还比较薄弱。通过理论计算,选择110kV变电站最优规模,并应用德国亚琛工业大学的大型可靠性分析程序RAMSES,对110kV电网典型接线方式的供电可靠性指标进行计算和分析比较,推荐了几种经济可靠的典型接线方式。
At present,the domestic research on network structures of 110 kV power network based on reliability of power supplies is very weak.Aimed at some network structures of 110 kV power network,this paper chooses the optimal capability of substation based on the theory calculation,calculates and compares the reliability of power supplies by the reliability calculating and analyzing software program of the RWTH Aachen University of Germany.Finally,based on the result of the reliability of power supplies,this paper recommends some reliable representative network structures of 110 kV power network.

关键词(KeyWords): 110kV电网;接线方式;RAMSES;可靠性
110 kV power network;network structures;RAMSES;reliability of power supplies