基于供电可靠性量化分析的110kV电网典型接线方式选择Determination of Representative Network Structures for 110 kV Power Networks Based on the Analysis of Reliability of Power Supplies
尹建兵,黄民翔,许诺
YIN Jian-bing 1,HUANG Min-xiang 2,XU Nuo 2(1.Hangzhou Municipal Electric Power Bureau
摘要(Abstract):
目前国内对110kV电网接线方式供电可靠性定量分析的研究还比较薄弱。通过理论计算,选择110kV变电站最优规模,并应用德国亚琛工业大学的大型可靠性分析程序RAMSES,对110kV电网典型接线方式的供电可靠性指标进行计算和分析比较,推荐了几种经济可靠的典型接线方式。
At present,the domestic research on network structures of 110 kV power network based on reliability of power supplies is very weak.Aimed at some network structures of 110 kV power network,this paper chooses the optimal capability of substation based on the theory calculation,calculates and compares the reliability of power supplies by the reliability calculating and analyzing software program of the RWTH Aachen University of Germany.Finally,based on the result of the reliability of power supplies,this paper recommends some reliable representative network structures of 110 kV power network.
关键词(KeyWords):
110kV电网;接线方式;RAMSES;可靠性
110 kV power network;network structures;RAMSES;reliability of power supplies
基金项目(Foundation):
作者(Author):
尹建兵,黄民翔,许诺
YIN Jian-bing 1,HUANG Min-xiang 2,XU Nuo 2(1.Hangzhou Municipal Electric Power Bureau
DOI: 10.19585/j.zjdl.2010.02.001
参考文献(References):
- 汪穗峰,张勇军,任倩,等.配电网可靠性定量分析研究综述[J].继电器,2008,36(3):79-83.
- 周云海,曹小伟,危雪.基于网络等值法的配电网可靠性研究[J].广东电力,2008,21(1):11-16.
- 王旭东,陈根永.配电网可靠性评估区间算法[J].郑州大学学报(工学版),2007,28(4):51-79.
- 万国成,任震,田翔.配电网可靠性评估的网络等值法模型研究[J].中国电机工程学报,2003,23(5):48-52.
- 万国成,任震,吴日昇,等.混合法在复杂配电网可靠性评估中的应用[J].2004,24(9):92-98.
- 王超,徐政,高慧敏.基于TPLAN的中国南方电网可靠性与经济性评估[J].继电器,2006,34(16):61-67.
- 张红云,毕鹏翔,钟筱军.中高压配电网可靠性分析系统开发及其应用[J].陕西电力,2007,35(12):29-32.
- 区伟潮,叶伯颖.高压配电网典型接线方式的可靠性分析[J].高电压技术,2006,32(2):106-107.
- E.LAKERVI(芬兰),E.J.HOLMES(英格兰).配电网络规划与设计[M].范明天,张祖平,岳宗斌,译.北京:中国电力出版社,1999.