基于电压故障分量的故障元件定位方法研究Research on Fault Element Location Method Based on Voltage Fault Component
胡晟,许路广,吴玉波
HU Sheng1,XU Lu-guang2,WU Yu-bo3(1.Jiashan Power Supply Bureau
摘要(Abstract):
根据故障点处电压故障分量最大这一基本原理,提出了WAMS(广域测量系统)中故障元件定位的新方法,即利用广域测量信息,找到电压故障分量最大的母线,并对其故障关联域内各元件进行差动计算来定位故障元件。当存在数据缺失时,则根据IED(智能电子设备)关联拓扑树扩大信息交换范围,以较大范围定位并切除故障。
In accordance to the basic principle that the voltage fault component is the maximum at the fault point,the paper proposes a new method for fault element location in WAMS(wide area measurement system). By use of wide area measurement system,the bus with maximum voltage fault component is confirmed,and the fault elements are located by differential calculation on elements in fault correlation area.In case there is loss of data,the information exchange area can be expanded on the basis of IED(intelligent electronic device), and the fault can be located and cleared in larger area.
关键词(KeyWords):
智能电网;广域测量系统;故障元件定位;电压故障分量;智能电子装置
smart grid;WAMS;fault element location;voltage fault component;IED
基金项目(Foundation):
作者(Author):
胡晟,许路广,吴玉波
HU Sheng1,XU Lu-guang2,WU Yu-bo3(1.Jiashan Power Supply Bureau
DOI: 10.19585/j.zjdl.2012.12.002
参考文献(References):
- 陈德树.大电网安全保护技术初探[J].电网技术,2004,28(9):14-17.
- 吕颖,张伯明,吴文传.基于增广状态估计的广域继电保护算法[J].电力系统自动化,2008,32(12):12-16.
- 苏盛,LI K K,CHAN W L.广域电流差动保护区划分专家系统[J].电网技术,2005,29(3):55-58.
- NAMDARIF,JAMALIS,CROSSL EYPA.广域保护中基于能量守恒原理的母线及输电线差动保护[J].电力系统自动化,2007,31(3):35-40.
- 马磊,王增平,马静.基于本地多信息的后备保护研究[J]继电器,2006,34(4):6-9.
- 丛伟,潘贞存,赵建国.基于纵联比较原理的广域继电保护算法研究[J].中国电机工程学报,2006,26(21):8-14.
- J.C.TAN,P.A.CROSSLEY,P.G.MCLAREN,et al..Application of a Wide Area Backup Protection Expert System to Prevent Cascading Outages[J].IEEE Transactions on Power Delivery,2002,17(2):375-380.
- 林霞,陆于平,王联合.分布式发电条件下的多电源故障区域定位新方法[J].电工技术学报,2008,23(11):139-145.
- 林霞,陆于平,王联合.含分布式电源的配电网智能电流保护策略[J].电网技术,2009,33(6):82-89.
- 葛耀中.新型继电保护和故障测距的原理与技术[M].西安:西安交通大学出版社,2007.
- 丛伟,潘贞存,赵建国.基于电流差动原理的广域继电保护系统[J].电网技术,2006,30(5):91-95.