变压器套管末屏适配器结构及其安全性研究Research on the structure and safety of transformer bushing tap adapter
夏健,左杰
XIA Jian,ZUO Jie
摘要(Abstract):
变压器套管在线监测需要末屏适配器引出末屏接地电流信号。统计某省电力公司主要变压器套管末屏接地结构,解决末屏适配器研制存在的问题,包括末屏信号引出的可靠性、适配器的防水密封性及耐久性、末屏信号外引的防开路保护及预试拆装的方便性以及末屏适配器的兼容性等。针对3种主要末屏结构分别研制了末屏适配器,并对其安全性进行了研究。结果表明,末屏适配器防尘、防水及抗振性能满足国家标准,在末屏开路时工频及雷电冲击电压下末屏适配器防开路保护装置均能可靠动作。
Tap adapter is necessary in online monitoring of transformer bushings to induct current connected to bushing tap. In this paper,earthing structures of transformer bushings in one provincial power grid are investigated. Problems including signal induct,waterproof and durability,open circuit protection,convenience of disassembly and assembly in preventive test and compatibility are handled. Aiming at 3 major earthing structures,3 types of interface adapters are designed and the safety of transformer bushing tap adapter are studied. The results show that dustproof,water-proof and vibration resistance performances of the tap adapter meet the national standards;when the bushing tap is open,open circuit protection device of the bushing tap adapter can operate reliably under power frequency and lightning impulse voltage.
关键词(KeyWords):
变压器套管;末屏适配器;末屏接地结构;可靠性
transformer bushing;tap adapter;tap earthing structure;reliability
基金项目(Foundation):
作者(Author):
夏健,左杰
XIA Jian,ZUO Jie
参考文献(References):
- [1]孙林,王梦云,翟向向,等.我国电力变压器发展现状及趋势[J].电力设备,2003,4(4):78-81.
- [2]王梦云.110 kV及以上变压器事故统计分析[J].供用电,2006,23(1):1-5.
- [3]王梦云.110 kV及以上变压器事故与缺陷统计分析[J].供用电,2007,24(1):1-5.
- [4]王梦云.2002~2003年国家电网公司系统变压器类事故统计与分析[J].电力设备,2004,5(10):20-26.
- [5]施逸,周国梁.一起由于套管密封失效导致的220 kV变压器故障分析[J].四川电力技术,2021,44(5):87-90.
- [6]李林,廖文龙,邓勇.一起110 kV主变压器套管受潮导致的故障分析.四川电力技术[J].2021,44(5):91-94.
- [7]洪志湖,颜冰,钱国超,等.一起110 k V油-油油纸绝缘变压器套管故障原因分析[J].变压器,2021,58(12):72-77.
- [8]廖波.某电站主变压器电容式套管爆炸分析及处理[J].水电与新能源.2021,35(7):73-75.
- [9]王昌长,李福祺,高胜友.电力设备的在线监测与故障诊断[M].北京:清华大学出版社,2006.
- [10]郝西伟,杨大伟,刘广艳,等.电容型变电设备绝缘在线监测系统的研制[J].高电压技术,2009,35(4):828-832.
- [11]李峰,孙旭东,王红斌,等.考虑气象环境影响的变压器套管介损监测预警策[J].高压电器,2017,53(7):159-166.
- [12] SETAYESHMEHR A,AKBARI A,BORSI H,et al.Online monitoring and diagnoses of power transformer bushings[J]. Dielectrics and Electrical Insulation,2006(7):608-615.
- [13]梁栋,朱建华,翟海文,等.基于DSP的变压器套管在线监测技术[J].电工技术,2021(14):122-123.
- [14]王楠,陈志业,律方成,等.电容型设备绝缘在线监测与诊断技术综述[J].电网技术,2003,27(8):72-76.
- [15]邹国平,何文林,孙翔.变压器套管在线监测接口适配器的研究[J].浙江电力,2013,10(9):7-10.
- [16]刘睿,张宗喜,冯运,等.基于多参数信息构建的变压器套管末屏状态评估方法[J].变压器,2021,58(10):37-40.
- [17]陈天翔,张保会,陈天韬,等.新型电容型电力设备tanδ在线高精确度测量系统[J].电力系统自动化,2004,28(15):67-70.
- [18]王永强,秦春旭,律方成,等.应用粗糙集分析电容型设备介损监测影响因素[J].高电压技术,2010,36(8):1970-1974.
- [19]中国标准化委员会.外壳防护等级(IP代码):GB 4208—2017/IEC 60529—2013[S].北京:中国质检出版社(速印),2017.
- [20]中国标准化委员会.电工电子产品环境试验:GB/T2423.10—2008/IEC 60068—2-6:199560529-2013[S].北京:中国标准出版社,2011.
- [21]李怡,王彤,曾彦珺.±800 kV直流穿墙套管对接结构接触状态评估方法[J].电瓷避雷器,2017(4):160-164.
- [22]伍弘,刘世涛,郝金鹏,等.运行负荷绝缘子芯棒-护套界面性能评估[J].电瓷避雷器,2022(2):153-158.