燃煤发电厂烟气超低排放管式GGH控制模式研究Study on the Tubular GGH Control Modes for Ultra-low Gas Emission of Coal-fired Power Plants
俞峰苹,李清毅,金军,陈文华
YU Fengping,LI Qingyi,JIN Jun,CHEN Wenhua
摘要(Abstract):
为解决回转式GGH漏风率较高的问题,诸多燃煤发电厂在烟气超低排放改造中增设了管式GGH系统,由于管式GGH系统应用较少,缺少运行控制经验。介绍了管式GGH系统组成,在机组启动、运行和停运阶段的控制模式和主要控制回路。管式GGH系统投运结果表明,烟气冷却器出口温度均能控制在92℃左右,系统运行良好。
To eliminate air leakage rate of rotary GGH(gas gas heater), many coal-fired power plants have adopted tubular GGH. As tubular GGH is seldom used and the relevant control and operation experience is insufficient. The paper introduces structure of tubular GGH and the control modes for units startup, operation and shutdown as well as main control circuits. The operation result of tubular GGH shows that gas temperature at the gas cooler outlet can be maintained at about 92 ℃ and the system is in sound operation.
关键词(KeyWords):
超低排放;管式GGH;控制模式;运行
ultra-low emission;tubular GGH;control mode;operation
基金项目(Foundation):
作者(Author):
俞峰苹,李清毅,金军,陈文华
YU Fengping,LI Qingyi,JIN Jun,CHEN Wenhua
DOI: 10.19585/j.zjdl.2015.09.018
参考文献(References):
- [1]王颖聪.湿法脱硫烟气石膏雨成因分析及处理方案综述[J].华北电力技术,2012(10):68-71.
- [2]武文江.石灰石-石膏湿法烟气脱硫技术[M].北京:中国水利水电出版社,2006.
- [3]张杰,任艳,张康,等.热管式GGH取代回转式GGH的可行性分析[J].建筑热能通风空调,2010,29(5):66-68.
- [4]彭大为,舒少辛,王义兵,等.脱硫系统GGH应用方案设计初探[J].中国电力,2012(2):52-55.
- [5]张瑞卿,杨海瑞,吕俊复.两级式低温烟气换热器运行效果评价[J].动力工程学报,2013,33(8):613-618.
- [6]李红,张全胜.燃煤火电厂脱硫系统烟气换热器密封技术改进及应用[J].发电设备,2014,28(4):310-312.