基于净烟气NOX浓度小时均值设定值的SCR智能控制优化
Intelligent Control Optimization of SCR Based on Hour-average Setpoint of NOX Concentration in Net Flue Gas

杨震力,冯晓露,张政江,张抗抗
YANG Zhenli,FENG Xiaolu,ZHANG Zhenjiang,ZHANG Kangkang

摘要(Abstract):

常规SCR(选择性催化还原法)控制方案中,SCR出口NO_X浓度或净烟气NO_X浓度设定值一般均为固定值。而目前我国的环保政策中对火电机组SCR出口NO_X浓度或净烟气NO_X浓度的的考核指标并不是采用其瞬时值的上限,而是采用小时均值。SCR智能控制优化方案中的净烟气NO_X浓度设定值采用基于小时均值的动态规划方式给出,这样的控制方案设计更匹配环保考核要求,更有利于在满足环保要求的前提下尽可能地节约SCR装置的喷氨量,从而最大限度地降低氨逃逸率。
In regular control scheme of SCR(selective catalytic reduction), NO_X or net flue gas concentration setpoint of SCR out-let is often a fixed value. However, the assessment standard for SCR outlet NO_X concentration or net flue gas NO_X concentration of existing national environmental protection policy is not the upper limit of the instantaneous value but the mean value of NO_X concentration. NO_X concentration setpoint of net flue gas is given by dynamic planning based on the hour-average value. This control scheme design better meets the environmental protection standard and saves the ammonia injection amount of SCR device as much as possible under the premise of meeting the requirements of environmental protection, and thereby minimizes the ammonia escape rate.

关键词(KeyWords): SCR智能控制优化;NO_X浓度设定值;动态规划;喷氨量;氨逃逸率
intelligent SCR control and optimization;NO_X concentration setpoint;dynamic planning;ammonia injection;ammonia escape rate reduction

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 杨震力,冯晓露,张政江,张抗抗
YANG Zhenli,FENG Xiaolu,ZHANG Zhenjiang,ZHANG Kangkang

DOI: 10.19585/j.zjdl.202003016

参考文献(References):

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享