浙江电力

2014, v.33;No.215(03) 42-45

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

600MW机组主汽调节阀组CFD流场分析及降压损改进
Analysis on CFD Flow Field of Main Steam Control Valves in 600 MW Steam Turbine and Improvement of Pressure Loss Reduction

吴志强,陶磊,李国明,杨晓伟,孙潜
WU Zhiqiang,TAO Lei,LI Guoming,YANG Xiaowei,SUN Qian

摘要(Abstract):

某600 MW发电机组自投产以来汽轮机高压主汽调节阀组存在压力损失偏大的问题。通过计算流体动力学CFD技术对阀组进行建模计算分析,并根据现场条件进行改造,有效解决了高压阀组压力损失大的问题,取得了明显的节能效果和经济效益。
The pressure loss of high-pressure main steam control valves of 600 MW steam turbine is great since the operation. By modeling of valves for calculation and analysis based on CFD(computer fluid dynamics) method and in combination with field practice, the valves are retrofitted, which effectively solves the problem of the great pressure loss of the valves and achieves significant energy savings and economic benefits.

关键词(KeyWords): 高压主汽调节阀组;CFD数据模拟;流场分析;600 MW
high-pressure main steam control valves;CFD data simulation;flow field analysis;600 MW

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 吴志强,陶磊,李国明,杨晓伟,孙潜
WU Zhiqiang,TAO Lei,LI Guoming,YANG Xiaowei,SUN Qian

DOI: 10.19585/j.zjdl.2014.03.012