浙江电力

2011, v.30;No.186(10) 49-52

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

215MW机组电除尘器的节能改造
Electrostatic Precipitator Energy-saving Upgrade in 215 MW Unit

林彦旻,周逸舟
LIN Yan-min,ZHOU Yi-zhou(Zhejiang Zheneng Zhenhai Power Generation Co.

摘要(Abstract):

根据电除尘器的除尘工作特性,结合电除尘器节能试验,利用节能优化控制方式能较大幅度地降低电除尘器运行电耗,提高经济效益。分析了新型电除尘节能技术的原理、技术特点,介绍了浙江浙能镇海发电有限责任公司4台215 MW机组电除尘器的改造与应用情况。
According to the operating characteristics of the electrostatic precipitator,we can greatly reduce the operating power consumption of the electrostatic precipitator and increase economic benefit using the energy-saving optimization control method combined with the energy-saving test.This paper analyzes the principles and the technical characteristics of the new electrostatic precipitator energy-saving technology and introduces the upgrade and application of the electrostatic precipitators for four 215 MW units of Zhejiang Zheneng Zhenhai Power Generation Co.,Ltd.

关键词(KeyWords): 电除尘器;节能降耗;改造
electrostatic precipitator;energy saving and consumption reduction;upgrade

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 林彦旻,周逸舟
LIN Yan-min,ZHOU Yi-zhou(Zhejiang Zheneng Zhenhai Power Generation Co.

DOI: 10.19585/j.zjdl.2011.10.015