浙江电力

2010, v.29;No.168(04) 34-36

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

电除尘能量管理系统运行优化
Running Optimization for the Energy Management System of Electrostatic Precipitator

林爱荣,周珠峰
LIN Ai-rong,ZHOU Zhu-feng(Guodian Zhejiang Beilun No.1 Power Generation Co.Ltd.

摘要(Abstract):

某发电厂原有电除尘器除尘效果不佳且能耗较大,通过设备改进和电除尘能量管理系统运行优化,确保了除尘效率达到设计要求,并降低了运行电耗。该运行优化方案对同类型设备具有一定的借鉴意义。
This paper introduces the principle of the electrostatic precipitator system,which used to operate in a high energy consumption and low dust-removal efficiency way in a power plant.By improvement and adjustment of energy management system of electrostatic precipitator,the design requirement was reached and the electricity consumption was reduced.This scheme made a reference for the same type equipments in our country.

关键词(KeyWords): 电除尘器;整流变;控制方式;振打;闭环控制;节能
electrostatic precipitator;rectifier transformer;control mode;vibration;close loop control;energy saving

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 林爱荣,周珠峰
LIN Ai-rong,ZHOU Zhu-feng(Guodian Zhejiang Beilun No.1 Power Generation Co.Ltd.

DOI: 10.19585/j.zjdl.2010.04.011