混流式水电机组转轮止漏环脱落的原因分析及处理Reason Analysis and Treatment for Runner Seal Ring Fall-off in Mixed Flow Unit
郑建锋,叶福新
ZHENG Jian-feng,YE Fu-xin (Zhejiang Huadian Wuxijiang Hydroelectric Power Plant
摘要(Abstract):
在分析某常规混流式水电机组转轮上部止漏环脱落原因的基础上,制定了详细的故障处理方案,处理效果较好,可为同类机组故障的处理提供借鉴。
This article introduces the whole discovery process,locale inspection and preliminary reason analysis about seal ring fall-off upside runner in mixed flow unit.According to the practical difficulties in inspection process,the paper brings forward countermeasures,management and preventive measures.
关键词(KeyWords):
混流式机组;转轮;上部止漏环;脱落;分析;处理
mixed flow unit;runner;seal ring;fall-off;analysis;management
基金项目(Foundation):
作者(Author):
郑建锋,叶福新
ZHENG Jian-feng,YE Fu-xin (Zhejiang Huadian Wuxijiang Hydroelectric Power Plant
DOI: 10.19585/j.zjdl.2010.01.011