浙江电力

2009, v.28;No.161(03) 48-50+60

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

超超临界直流锅炉氧化铁沉积分析及对策
Analysis and Countermeasures for Magnetic Ferric-oxide Sediment in Ultra-supercritical Once-through Boiler

邵天佑,闻国华
SHAO Tian-you,WEN Guo-hua(Huaneng Yuhuan Power Plant

摘要(Abstract):

通过介绍超超临界状态水的物理化学特性,分析超超临界直流锅炉炉前水系统磁性氧化铁产生、沉积原因以及聚集结垢对锅炉水冷壁管的危害,提出做好预防及处理磁性氧化铁沉积问题的方法,减少锅炉爆管,提高机组安全可靠性。
After introducing the characteristics of water under(ultra) supercritical state, this paper analyzes the reason of occuring and sediment of magnetic ferric-oxide in the boiler-front system of ultra-supercritical once-through boiler.and the danger caused to the boiler water wall by accumulation of the magnetic ferric-oxide. Then it puts forward the methods for preventing and treating with the sediment of the magnetic ferric-oxide, thus reducing boiler tube explosion and increasing the safety and reliability of the power generating units.

关键词(KeyWords): 超超临界;直流锅炉;磁性氧化铁;沉积
ultra-supercritical; once-through boiler; magnetic ferric-oxide; sediment

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 邵天佑,闻国华
SHAO Tian-you,WEN Guo-hua(Huaneng Yuhuan Power Plant

DOI: 10.19585/j.zjdl.2009.03.014