350MW超临界机组甩负荷试验过程分析Analysis on the Load Rejection of HTC 350 MW Supercritical Steam Turbine
安欣,李续军,张亚夫,刘国弼
AN Xin,LI Xu-jun,ZHANG Ya-fu,LIU Guo-bi (Xi'an Thermal Power Research Institute Co. Ltd.
摘要(Abstract):
介绍了哈汽350MW超临界机组50%及100%甩负荷试验工况下调节系统的运行和调节特性,计算了机组调节系统的特性参数,并对试验中出现的问题进行了分析,对同类型机组甩负荷试验提出了建议。
This paper introduced regulator system operation and regulation characteristics of the 350 MW supercritical units. Through the 50% and 100% load rejection test,this paper analyzed the problem in the process and calculated the dynamic parameters of the regulator system,made a number of recommendations to the load rejection for the other same type power units.
关键词(KeyWords):
350MW机组;超临界;甩负荷;调节系统;特性参数
350 MW unit; supercritical; load rejection; regulator system; dynamic parameter