浙江电力

2013, v.32;No.206(06) 51-53

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

钢102材料运行后的组织性能变化及原因分析
Structure Property Variation and Cause Analysis of 12Cr2MoWVTiB Steel after Operation

楼玉民,杨点中,胡洁梓
LOU Yu-min,YANG Dian-zhong,HU Jie-zi(Z(P)EPC Electric Power Research Institute

摘要(Abstract):

总结了浙江省内各类机组钢102材料受热面管运行后,力学性能、金相组织、内壁氧化皮厚度等方面的变化规律,结合机组实际运行工况,分析了这些变化导致爆管的原因,并提出相关建议。
The paper sums up variation rules of mechanical properties,metallographic structure,firecoat thickness of inner wall after operation of 12Cr2MoWVTiB steel heating surface pipes of units in Zhejiang Province.By combining practical operational state of units,the paper analyzes the causes for pipeburst and proposes relevant suggestions.

关键词(KeyWords): 钢102材料;性能变化;原因
2Cr2MoWVTiB steel;variation of property;cause

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 楼玉民,杨点中,胡洁梓
LOU Yu-min,YANG Dian-zhong,HU Jie-zi(Z(P)EPC Electric Power Research Institute

DOI: 10.19585/j.zjdl.2013.06.015

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享