直流电压测量装置中绝缘气体瞬态流动影响研究Study on the influence of transient flow of insulating gas in DC voltage measurement device
张旭乐,张浩哲,陈刚
ZHANG Xule,ZHANG Haozhe,CHEN Gang
摘要(Abstract):
直流电压测量装置是重要的一次测量设备,在特殊工况下对其进行SF6带电补气作业时,应保证在充气瞬态过程中不会因SF6压强突变而发生直流系统告警或闭锁。对此,建立了直流电压测量装置密封气路等效模型,通过有限元方法对在不同阀口位置充气时SF6瞬态流动特性进行仿真计算和对比分析,发现管状气路末端充气时SF6气压监测表计压强变化较大,易导致直流系统发生告警或闭锁。通过在不同阀口位置进行充气试验,验证了压强变化与仿真结果基本一致。基于不同阀口充气时SF6瞬态流动压强变化的研究,对于直流电压测量装置带电补气操作具有工程指导意义。
The DC voltage measurement device is an important primary measurement equipment. In case of live refilling of SF6 under special operating conditions, it should be ensured that no DC system alarm or lockout will occur during the transient refilling due to sudden change of SF6 pressure. In this regard, an equivalent model of sealed gas paths of DC voltage measurement device is established. The transient flow characteristics of SF6 are simulated and comparatively analyzed by finite element method when the gas is refilled at different valve ports. It is found that the gauge pressure of SF6 varies greatly when refilled at the end of the tubular gas path, which easily leads to alarm or lockout in the DC system. By refilling tests at different valve port positions, it is verified that the pressure change is on the whole consistent with the simulation results. The study of transient flow pressure changes of SF6 during refilling at different valve ports is of significance to engineering guidance for the live refilling of the DC voltage measurement device.
关键词(KeyWords):
直流电压测量装置;压强;绝缘气体
DC voltage measurement device;pressure;insulating gas
基金项目(Foundation): 国网江苏省电力有限公司科技项目(J2021074)
作者(Author):
张旭乐,张浩哲,陈刚
ZHANG Xule,ZHANG Haozhe,CHEN Gang
DOI: 10.19585/j.zjdl.202303008
参考文献(References):
- [1]安海清,李振动,金海望,等.张北柔直电网直流分压器二次电压测量异常引起误闭锁机理分析及改进措施[J].电力自动化设备,2021,41(8):156-160.AN Haiqing,LI Zhendong,JIN Haiwang,et al. Mechanism analysis and improvement measures of error block caused by abnormal secondary voltage measurement of DC voltage divider in Zhangbei flexible DC grid[J].Electric Power Automation Equipment,2021,41(8):156-160.
- [2]滕予非,李小鹏,焦在滨,等.特高压直流分压器传变特性及其对电压突变量保护影响[J].电力系统保护与控制,2019,47(23):122-130.TENG Yufei,LI Xiaopeng,JIAO Zaibin,et al.Analysis of the transfer characteristic of DC voltage divider in UHVDC system and its effects on undervoltage sensing protection[J]. Power System Protection and Control,2019,47(23):122-130.
- [3]滕予非,汤涌,汪晓华,等.特高压直流输电工程直流分压器动态特性及其引起的误闭锁机理研究[J].电网技术,2016,40(9):2646-2653.TENG Yufei,TANG Yong,WANG Xiaohua,et al.Mechanism analysis of error block caused by dynamic characteristics of DC voltage divider in UHVDC[J]. Power System Technology,2016,40(9):2646-2653.
- [4]孙哲,李彦斌,张兆华,等.特高压换流站直流分压器二次侧过电压保护[J].电网技术,2019,43(7):2601-2609.SUN Zhe,LI Yanbin,ZHANG Zhaohua,et al. Study on surge protection of DC divider secondary side in UHV converter station[J].Power System Technology,2019,43(7):2601-2609.
- [5]冯建华,王珊,赵力楠,等.特高压直流电压测量装置内部温度分布研究[J].高压电器,2016,52(6):41-45.FENG Jianhua,WANG Shan,ZHAO Linan,et al.Study on the internal temperature distribution of UHVDC voltage measuring device[J].High Voltage Apparatus,2016,52(6):41-45.
- [6]刘伟,叶艳军,胡继华,等.800 kV直流电压测量装置原理及绝缘结构分析[J].电网与清洁能源,2019,35(7):45-54.LIU Wei,YE Yanjun,HU Jihua,et al.Principle and insulation structure analysis of the 800 kV DC voltage measuring device[J].Power System and Clean Energy,2019,35(7):45-54.
- [7]邵明鑫,王晓琪,汪本进,等.特高压直流分压器内部温度场结构优化设计[J].高压电器,2016,52(9):8-13.SHAO Mingxin,WANG Xiaoqi,WANG Benjin,et al.Optimized design for HVDC voltage divider internal temperature field[J].High Voltage Apparatus,2016,52(9):8-13.
- [8]蔡涛.特高压换流站直流分压器原理及故障处理[J].电力安全技术,2022,24(4):63-64.CAI Tao.Principle and fault treatment of DC voltage divider in UHV converter stations[J].Electric Safety Technology,2022,24(4):63-64.
- [9]霍鹏飞,王国功,刘敏,等.向上±800 kV特高压直流输电工程的直流保护闭锁策略[J].电力系统保护与控制,2011,39(9):137-139.HUO Pengfei,WANG Guogong,LIU Min,et al.The DC protection block strategy in Xiangjiaba-Shanghai±800kV UHVDC transmission project[J].Power System Protection and Control,2011,39(9):137-139.
- [10]唐登平,郑欣,雷鸣,等.直流电子式电压互感器的误差特性分析[J].电测与仪表,2021,58(2):107-111.TANG Dengping,ZHENG Xin,LEI Ming,et al. Error characteristic analysis of DC electronic voltage transformer[J].Electrical Measurement&Instrumentation,2021,58(2):107-111.
- [11]刘立斌,刘春玉,胡继华,等.特高压直流电压测量装置二次分压及数字采集技术研究与应用[J].电网与清洁能源,2019,35(8):34-41.LIU Libin,LIU Chunyu,HU Jihua,et al.Research and application of secondary voltage division and digital acquisition technology of UHVDC voltage measuring equipment[J].Power System and Clean Energy,2019,35(8):34-41.
- [12]李坤.±1 100 kV特高压直流电压互感器电压测量装置及其在线监测系统研究[D].武汉:华中科技大学,2017.LI Kun. Research on voltage measurement device of±1100 kV UHVDC voltage transformer and its on-line monitoring system[D]. Wuhan:Huazhong University of Science and Technology,2017.
- [13]周启义,张泽强,顾军,等.一种SF6气体密度继电器校验用的装配接头的研制[J].高压电器,2015,51(10):145-149.ZHOU Qiyi,ZHANG Zeqiang,GU Jun,et al. Development of an assembly joint for calibration on SF6 gas density monitor[J].High Voltage Apparatus,2015,51(10):145-149.
- [14]汪本进,王睿晗,吴士普,等.特高压直流电压互感器换热结构设计及其对误差特性的影响研究[J].电测与仪表,2022,59(1):84-92.WANG Benjin,WANG Ruihan,WU Shipu,et al. Research on the heat exchange structure designing for UHV DCVT and its influence on error characteristics[J].Electrical Measurement&Instrumentation,2022,59(1):84-92.