基于海上风电发展趋于深远海化的现状,针对海上风电送出方式选择问题,从经济性层面对柔性直流和低频交流两种海上风电送出方案做出评估。运用现金流折现的方法,结合装机容量1 000 MW、离岸距离100 km的典型远海风电场景,从工程投资和运维费用等方面开展了研究。结果表明,相较于柔性直流方案,低频交流输电在中远距离海上风电送出场景下具有一定的经济优势。同时,比较了风机采用35 kV和66 kV两种汇集电压的经济性,得出66 kV汇集方案更具经济性的结论。
Since offshore wind power tends towards deep sea,the paper evaluates two offshore wind power transmission schemes,namely flexible DC transmission and low-frequency alternating current(LFAC)from the economic perspective. Discounted cash flow(DCF)is used,and a typical scenario with an installed capacity of 1 000 MW and an offshore distance of 100 kilometers is combined to study engineering investment and operation and maintenance costs. The results show that LFAC power transmission owns economic superiority in the scenario of medium and long-distance offshore wind power transmission. The convergence voltage of 35 kV and 66 kV used for wind power generators are compared regarding economy. It is concluded that the latter is more economical.
关键词(KeyWords):
远海风电;柔性直流;低频交流;汇集系统;经济性评估
offshore wind power;flexible DC transmission;low-frequency alternative current;convergence system;economic evaluation
基金项目(Foundation): 国网浙江省电力有限公司科技项目(2021ZK04)
作者(Author):
黄晓尧,谢瑞,裘鹏,倪晓军
HUANG Xiaoyao,XIE Rui,QIU Peng,NI Xiaojun
DOI: 10.19585/j.zjdl.202207001
参考文献(References):
- [1] DIAZ H,GUEDES SOARES C. Review of the current status,technology and future trends of offshore wind farms[J].Ocean Engineering,2020,209:107381.
- [2]王秀丽,赵勃扬,黄明煌,等.大规模深远海风电送出方式比较及集成设计关键技术研究[J].全球能源互联网,2019,2(2):138-145.
- [3]程斌杰,徐政,宣耀伟,等.海底交直流电缆输电系统经济性比较[J].电力建设,2014,35(12):131-136.
- [4] MACHADO J,NEVES M V,SANTOS P J.Economic limitations of the HVAC transmission system when applied to offshore wind farms[C]//2015 9th International Conference on Compatibility and Power Electronics(CPE). June 24-26,2015,Costa da Caparica,Portugal.IEEE,2015:69-75.
- [5] VAN EECKHOUT B,VAN HERTEM D,REZA M,et al. Economic comparison of VSC HVDC and HVAC as transmission system for a 300 MW offshore wind farm[J].European Transactions on Electrical Power,2010,20(5):661-671.
- [6] LAURIA S,SCHEMBARI M,PALONE F,et al.Very long distance connection of gigawatt-size offshore wind farms:extra high-voltage AC versus high-voltage DC cost comparison[J].IET Renewable Power Generation,2016,10(5):713-720.
- [7]张昭丞,郭佳田,诸浩君,等.基于全生命周期成本的海上风电并网方案优选分析[J].电力系统保护与控制,2017,45(21):51-57.
- [8]徐进,韦古强,金逸,等.江苏如东海上风电场并网方式及经济性分析[J].高电压技术,2017,43(1):74-81.
- [9]王锡凡,刘沈全,宋卓彦,等.分频海上风电系统的技术经济分析[J].电力系统自动化,2015,39(3):43-50.
- [10] WANG X F,TENG Y F,NING L H,et al.Feasibility of integrating large wind farm via fractional frequency transmission system a case study[J].International Transactions on Electrical Energy Systems,2014,24(1):64-74.
- [11]黄明煌,王秀丽,刘沈全,等.分频输电应用于深远海风电并网的技术经济性分析[J].电力系统自动化,2019,43(5):167-174.
- [12] RUDDY J,MEERE R,O’DONNELL T.A comparison of VSC-HVDC with low frequency AC for offshore wind farm design and interconnection[J]. Energy Procedia,2015,80:185-192.
- [13]汪大洋,刘宗烨,李沛,等.基于模块化多电平矩阵换流器的海上风电低频系统经济性分析[J].分布式能源,2018,3(2):16-22.
- [14]刘志远.分频输电系统中真空断路器的开断性能[J].高压电器,2011,47(4):101-103.
- [15] FISCHER W,BRAUN R,ERLICH I. Low frequency high voltage offshore grid for transmission of renewable power[C]//IEEE PES Innovative Smart Grid Technologies Europe(ISGT Europe),Oct. 14-17,2012,Berlin,Germany.IEEE,2012:1-6.
- [16] GATTA F M,GERI A,LAURIA S,et al.Steady-state operating conditions of very long EHVAC cable lines[J].Electric Power Systems Research,2011,81(7):1525-1533.
- [17]林进钿,倪晓军,裘鹏.柔性低频交流输电技术研究综述[J].浙江电力,2021,40(10):42-50.
- [18]徐政,张哲任.低频输电技术原理之一——M3C的数学模型与等效电路[J].浙江电力,2021,40(10):13-21.
- [19]张蕾,许挺.世界首个柔性低频输电工程正式落点浙江杭州[J].新能源科技,2021(6):11.
- [20]蔡蓉,张立波,程濛,等.66 kV海上风电交流集电方案技术经济性研究[J].全球能源互联网,2019,2(2):155-162.
- [21]刘卫东,徐晗,冯嘉琦,等.66 kV集电线路的海上风电柔直送出方案技术经济性研究[C]//2020年中国通信学会能源互联网学术报告会论文集.中国通信学会能源互联网委员会、中国电力科学研究院有限公司:5.