应用多级有源滤波系统的分布式电源谐波治理Distributed Power Harmonic Control Based on a Multi-level Active Filtering System
吴昊,方旭光,贾立忠,蒋嵘,王敏,徐勇俊,柳延洪
WU Hao,FANG Xuguang,JIA Lizhong,JIANG Rong,WANG Min,XU Yongjun,LIU Yanhong
摘要(Abstract):
有源滤波器是配电网谐波治理的动态补偿装置,但分布式电源的接入造成配电网谐波变得复杂,单一的有源滤波器在补偿线路谐波方面难以达到效果。设计了一种多级有源滤波系统,将补偿源设置在各电源母线处,得到一组含多个补偿源的分布式电源接入的配电网模型,通过调节滞环宽度,稳定开关频率。采用改进后的滞环空间矢量控制对各有源滤波单元分别进行控制,并基于MATLAB/Simulink仿真平台,分别搭建了含单一滤波器和两级有源滤波系统的分布式电源接入的配电网仿真模型,仿真对比分析了谐波治理的效果,仿真结果验证了多级有源滤波系统对分布式电源接入的配电网谐波治理的有效性和可行性。
Active filter is a dynamic compensation device for harmonic control in the distribution network.However, the access of the distributed generation causes the complexity of the harmonics of the distribution network, and the single active filter can hardly compensate the line harmonics. In this paper, a multi-stage active filtering system is designed. The compensation source is set at each power bus, and a distribution network model with distributed power supply and multiple compensation sources is obtained, which stabilizes switching frequency through hysteresis space adjustment. The improved hysteresis space vector control is used to govern the active filtering units, and the distributed generation with a single filter and multi-stage active filter system is built based on MATLAB/Simulink simulation platform. The network simulation model compares and analyzes the effects of single filtering and multi-stage active filtering system on harmonics control in the distributed distribution network. The simulation results verify the effectiveness and feasibility of a multi-stage active filtering system in distribution network harmonic control with the access of distributed generation.
关键词(KeyWords):
分布式电源;多级有源滤波;配电网;谐波治理
distributed generation;multi-stage active filtering;distribution network;harmonics control
基金项目(Foundation): 国网浙江省电力有限公司金华供电公司科技项目(5211JH17000A)
作者(Author):
吴昊,方旭光,贾立忠,蒋嵘,王敏,徐勇俊,柳延洪
WU Hao,FANG Xuguang,JIA Lizhong,JIANG Rong,WANG Min,XU Yongjun,LIU Yanhong
DOI: 10.19585/j.zjdl.202001006
参考文献(References):
- [1]李广兵,蒲玉兴.并联型有源电力滤波器新型谐波检测方法研究[J].电力电容器与无功补偿,2018,39(4):7-11.
- [2]李建民.浅谈配电网谐波的危害及其治理措施[J].科技创新与应用,2014(34):155.
- [3]吴鸣,于辉,熊雄.分布式电源接入配电网的基本原则[J].供用电,2017,34(12):32-38.
- [4]孟晓芳,王立地,王小宁,等.利用分布式电源改善三相四线低压配电网运行特性方法[J].电网技术,2018(12):4091-4100.
- [5]康成功,李献伟,张国军.分布式电源参与的配电网电能质量控制策略研究[J].电力系统保护与控制,2016,44(16):99-105.
- [6]朱燕.分布式有源滤波系统的研究[D].重庆:重庆大学,2006.
- [7]曾正,赵荣祥,杨欢,等.多功能并网逆变器及其在微电网电能质量定制中的应用[J].电网技术,2012,36(5):58-67.
- [8]冯尧.微电网谐波治理方法的研究[D].沈阳:沈阳工业大学,2017.
- [9]曹红娟,张兴良.配电网无功补偿和谐波治理措施探讨[J].科技创新与应用,2015(36):188.
- [10]应龙,刘晓松.浅谈10 kV配电线路谐波治理和节能降损[J].中国高新技术企业,2015(36):81-82.
- [11]董萌钊.电力系统用户谐波原因分析和治理[J].通讯世界,2015(21):192-193.
- [12]王业铨,刘建东,张啸,等.低压配电网三次谐波电流的检测与分析[J].北京石油化工学院学报,2015,23(3):54-57.
- [13]吴培锦.浅析谐波对电能质量的危害及其治理措施[J].机电信息,2015(24):91-92.
- [14]黄川,周益,陈家良.低压有源滤波器在用户侧谐波治理中的应用[J].华东电力,2014,42(12):2560-2563.
- [15]周钰苑.电力系统谐波抑制方法分析[J].电气开关,2012,50(6):78-80.
- [16]陈磊,符仕浩,成佳斌,等.分布式发电系统并网逆变器高稳态性能重复控制策略[J].浙江电力,2019,38(10):6-11.
- [17]印然.基于IGG抗差最小二乘法的三相配电网谐波状态估计[J].电力大数据,2018,21(4):69-72.
- 分布式电源
- 多级有源滤波
- 配电网
- 谐波治理
distributed generation - multi-stage active filtering
- distribution network
- harmonics control